Light electromagnetic feeder, open tray — 3D drawing Representative 3D drawing for this feeder design

Vibrating feeder ПЭВ 360/215х1250-25

Electromagnetic vibrating feeder, light feeders, open tray · drive ВЭМ-Л3

The ПЭВ 360/215х1250-25 has an open trough of 360 × 1250 mm, a maximum throughput of 25 m³/h and a lump size up to 50 mm. It differs from the shorter model of the same rating in its ВЭМ-Л3 drive and a mass of 250 kg against 135 kg: a longer trough calls for a stronger drive. Supply is 380 V, 50 Hz, coil voltage 0–300 V, current up to 7 A, dimensions within 1570×590×670 mm.

Tray width / length360 × 1250 mm
Max. capacity*25 m³/h
Max. lump size50 mm
Tray designOpen
Drive typeElectromagnetic, однотактный, ВЭМ-Л3
Drive positionНижнее
Power supply380 V, 50 Hz
Coil voltage range0–300 V
Coil current, max7 A
Dimensions (L×W×H), max1570×590×670 mm
Mass (excl. isolators & controller)250 kg

* Capacity measured on dry sand (bulk density 1.52 kg/dm³) at standard tray incline; adjustable from zero to maximum via the control unit.

Supply terms: 2–4 weeks lead time, 12-month warranty from the shipment date. details →
Need this model or something similar?
We reply within one business day
Request a quote
📋
Selection questionnaire
Fill in the material parameters and required capacity — this lets us size a model and quote it faster and more accurately. Download PDF →

Where it is used

How it differs from neighbouring models

Questions and answers

How does it differ from the ПЭВ 360/215х940-25?

In trough length and drive. At the same 25 m³/h and the same cross-section, the 1250 mm model uses a ВЭМ-Л3 drive with current up to 7 A and coil voltage up to 300 V, and weighs 250 kg against 135 kg for the 940 mm model.

What lump size suits this model?

No more than 50 mm. Coarser material calls for models 500 mm wide and up, where the limit is 90 mm, or the 700 mm wide model at 160 mm.

How much space does the feeder occupy?

Dimensions stay within 1570×590×670 mm. The drive is bottom-mounted, so the layout has to allow access beneath the trough and room for vibration isolators.

How the price is calculated

We do not publish prices: cost is calculated for the specific duty — tray design and lining, control cabinet or unit, climatic version, batch size and delivery terms. Send us the material parameters and the throughput you need.

Request a quote
We reply within one working day
Request a quote