Heavy electromagnetic feeder, bottom-mounted drive — 3D drawing Representative 3D drawing for this feeder design

Vibrating feeder ПЭВФ 1200/410х2000-150

Electromagnetic vibrating feeder, heavy feeders, bottom-mounted drive · drive ВЭМ-Т2

The PEVF 1200/410х2000-150 is a heavy-duty feeder with a bottom-mounted drive: a 1200 × 2000 mm trough, maximum throughput 150 m³/h and a lump size up to 320 mm. It uses a VEM-T2 drive, coil current up to 13 A, coil voltage 0–310 V, supply 380 V, 50 Hz. Mass excluding vibration isolators and the control unit is 1600 kg, dimensions within 2400×1530×1130 mm. It is the shortest option in the 1200 mm range.

Tray width / length1200 × 2000 mm
Max. capacity*150 m³/h
Max. lump size320 mm
Tray designOpen
Tray materialСталь 09Г2С (опция футеровки Hardox 400/450)
Drive typeElectromagnetic, однотактный, ВЭМ-Т2
Drive positionНижнее
Power supply380 V, 50 Hz
Coil voltage range0–310 V
Coil current, max13 A
Dimensions (L×W×H), max2400×1530×1130 mm
Mass (excl. isolators & controller)1600 kg

* Capacity measured on dry sand (bulk density 1.52 kg/dm³) at standard tray incline; adjustable from zero to maximum via the control unit.

Supply terms: 2–4 weeks lead time, 12-month warranty from the shipment date. details →
Need this model or something similar?
We reply within one business day
Request a quote
📋
Selection questionnaire
Fill in the material parameters and required capacity — this lets us size a model and quote it faster and more accurately. Download PDF →

Where it is used

How it differs from neighbouring models

Questions and answers

What is the largest lump the feeder accepts?

Up to 320 mm. That is heavy-duty territory: 950 mm wide models stop at 250 mm, 1400 mm models reach 380 mm and 1500 mm models 400 mm.

How does a bottom-mounted drive differ from a top-mounted one?

On this model the drive sits beneath the trough; on the PEVVF of the same size it sits above. That changes station layout, service access and overall height — here the height is 1130 mm.

What electrical supply does the VEM-T2 drive need?

380 V, 50 Hz, coil voltage 0–310 V and coil current no more than 13 A. Output is set smoothly by the control cabinet, from zero up to 150 m³/h.

How the price is calculated

We do not publish prices: cost is calculated for the specific duty — tray design and lining, control cabinet or unit, climatic version, batch size and delivery terms. Send us the material parameters and the throughput you need.

Request a quote
We reply within one working day
Request a quote